The Nanoscale Biophotonics Laboratory has been developing one of the most advanced fluorescence microscopy facilities in Ireland.
We currently operate four confocal and one TIRF systems (4 fluorescence and 1 Raman). These systems are used for a variety of materials science and biological applications.
These are all now located in the
School of Chemistry in a dedicated laboratory (see pictures below).
|
|
| R166 lab, late 2008: Upright FLIM system
|
R166 lab, late 2008: TIRF system.
|
|
![]() |
| R166 lab, late 2008: Raman & VCM100 confocal
|
R166 lab, late 2008: Inverted FLIM/FCS system.
|
![]() |
![]() |
(Jan. 2008 spec.)
This ISS system has 470 & 532 nm excitation sources to enable 2 channel cross correlation experiments to be conducted. In Jan. 2008 it was further upgraded with a microscope incubator from Solent Scientific. Funding for this enhancement was provided under the HEA funded (PRTLI-IV) National Biophotonics Imaging Platform. This will facilitate live cell studies using FCS and FLIM methods. The chamber is rated for 32C to 40C and a CO2 system will also be fitted. The system is also equipped with an Electron Multiplying CCD (EMCCD) Camera for ultra-low light imaging. The EMCCD is an Andor Luca system which we are using for some proof of concept studies. The medium term plan is to source a higher specification camera for single molecule studies. |
| (2005 Picture, original spec.)
This system has 470 & 532 nm excitation sources to enable 2 channel cross correlation experiments to be conducted (Biochemistry Dept. projects with HP Nasheuer and Ian Dobbie). In addition the system has full FLIM capability with 2 wavelength channels, motorized XYZ stage (nm resolution), and a range of high performance objectives. The microscope objectives are compatible with our existing fluorescence and Raman microscopy systems. In 2007 the system was upgraded with a fibre coupled laser delivery system. |
![]() |
Some sample data from the inverted system is illustrated below:
![]() |
![]() |
![]() |
![]() |
Cells provided by Dr. Michael Ball, ex. of NCBES, who was using FLIM to study cell biomaterial interactions.
This system has also been used for FCS measurements from live cells. An FCS page is under construction to show some of these results.
|
|
The upright FLIM microscope for materials
science and photophysics applications. The system became operational
in June 2005 and is based on the Alba system from
ISS.
It comprises of an upright Olympus microscope, equipped with both a micrometer stepper motor and piezo nanopositioning stage. The detector system has two independent channels for dual colour FLIM imaging, and dual colour FCS. The excitation sources are 405 & 635 nm modulated laser diodes, as well as an epifluorescence illuminator for wide field imaging.
|
![]() |
This system was built by a PhD student, Richard Murray.
The system used a fast gated ICCD camera from Stanford Computer Optics to generate time-gated images from which Fluorescence Lifetime Images can be constructed. The Camera is a 4 Picos which is capable of producing a minimum time gate of about 200 picoseconds. The excitation source is a PicoQuant 405 nm pulsed laser diode. This was used for FLIM analysis of Hydrocarbon Bearing Fluid Inclusions. This has now been retired from use. |
|
A confocal scanning lifetime microscope system is to be constructed
for materials analysis using TCSPC measurement methods.
It will utilize existing components and accommodate the humidity chamber and eventually a heating-freezing stage. This system will use a PicoQuant PicoHarp300 TCSPC measurement system, pulsed laser diode excitation, and a ThorLabs VCM100 Confocal scanner (shown left). This will allow for FLIM and FCS measurements to be undertaken. We will use this system for exploratory studies in materials science, particularly for polymer systems and metal enhanced fluorescence studies. The system was delivered in May 2008. It is fitted with a dual laser source (405 and 635 nm) for conventional fluorescence imaging. This facility was provided under the HEA funded (PRTLI-IV) National Biophotonics Imaging Platform. More details will be added as the system is modified and adapted. |
![]() |
![]() |
| The image above shows the complete system with PC control.
The scan unit is at the top with two yellow single mode fibres
attached. The two boxes immediately to the rear accommodate the lasers,
detectors, and control electronics.
|
This close up shows the basic construction of the LSCM with a motorised stage and a relatively open optical path suitable for easy modification. The stage is PC controlled with XYZ travel at sub-micron resolution.
|
![]() |
| Triple line TIRF system located in Lab166. The
Andor EMCCD Camera is on the left, the TIRF illuminators at rear of microscope
|
![]() |
![]() |
| Left rear of TIRF setup, showing 488 nm laser input via single mode FC fibre. The micrometer screw allows for adjustment of laser input angle. | Right rear of TIRF setup, showing 405 nm laser input via single mode FC fibre. The micrometer screw allows for adjustment of laser input angle. The oblong box is the laser safety shutter. |
| A
VGI 2000M
custom built humidity chamber (right) for microscopy and spectroscopy was commissioned in Jan. 2008. This is heavily
used for polymer studies.
The system can be fitted to most of the Raman or Fluorescence microscopy systems. We have also acquired a CO2 perfusion system and chamber for live cell imaging which can be fitted to the Inverted FLIM-FCS system. We also have a variety of cell and sample holders for static measurements. As we acquire more equipment and accessories I will update the webpages with details and photos. |
|
A microscope based system for fluorescence lifetime measurement (lifetimes < 0.3 ns, resolution <10 microns) was built as a Ph.D. research project by two students (M. Przyjalgowski and B. Szczupak) and was used for the study of fluorophore labeled polymer films, nanoparticle coated microspheres, and microscopic hydrocarbon bearing fluid inclusions.
![]() |
The picture (left) shows the microscope system in operation. The excitation source, coupling optics, and detection system were all mounted above the microscope (as shown in the lower picture), in a light tight enclosure that can be easily opened for alignment.
The major system components are a pulsed 404 nm laser diode (PicoQuant), an Olympus BX-60 microscope, a 0.10 m focal length monochromator (Scientech 9030) controlled by STP-240 stepper motor controller.
The detector was a
Hamamatsu H5783P-01 photon counting PMT module and the output of which was fed to a
SPC-730 TCSPC card integrated into a standard PC.
Funding for this project came from the National Centre for Biomedical Engineering Science. |
| The laser source is at the bottom left, most of the package contains the peltier cooler which keeps the diode at an operating temperature of ~20° C for stable wavelength and power output.
The PMT detector is mounted onto the exit port of the monochromator (top).
|
![]() |
![]() |
The plot on the left shows how the temporal width (FWHM) of the Instrument Response Function (IRF) varies with the laser power. For the LDH-400 violet laser diode, lasing does not occur until the power setting on the dial exceeds ~ 30%, this results in a broad ASE and hence a large FWHM value. The FWHM drops rapidly as lasing increases and above ~ 60% power the IRF remains nearly constant at ~270 picoseconds. This value is the limit of the system and is determined by the detector which is an uncooled PMT and as such is not capable of better temporal resolution. To improve the temporal resolution further we need a MCP (Multichannel Plate) detector which would allow us to reduce the FWHM to ~ 70 picoseconds, which is the temporal width of the laser pulses. |
We also developed a motorised X-Y scanning stage for the DLFLM. In 2005, we replaced the DLFLM with dedicated FLIM systems (see Alba above). The microscope frame and components from the DLFLM are being used to build a gated ICCD-FLIM system and a fibre coupled TCSPC module for TRES and lifetime studies. We hope to be able to couple this module to any of the microscopy systems we have in-house.
Old views of the lab:
|
![]() |
| R166 showing the confocal Raman (right) and Thorlabs VCM100 confocal at left.
In the immediate rear is the ISS FLIM-FCS confocal system (Oct. 2008). |
Another view of the microscopy lab showing the VCM100 and the rear of the confocal Raman.
|
![]() |
![]() |
| This is the inverted FLIM-FCS system which has been moved into
it's new room. It will be reassembled by the end of October and fully
configured for live cell work.
|
This is what lab 166 looked like before we moved everything in.
|