Prof Peter McHugh B.E., Sc.M.,PH.D.
Contact Details
|
|
Biography:
Research Interests
| One of my main areas of research has been in applying computational micromechanics techniques, including finite element methods, to understand and predict the mechanical behaviour of materials during processing and in-service conditions, for example new generation advanced materials such as metal matrix composites, structurally graded tungsten carbide, nickel based superalloys and surface coated steels and alloys. I have become increasingly interested in physical and mechanical testing of materials and I have developed significant expertise in this area. Under my direction, the micromechanics research area has flourished at the University and I have attracted significant research funding, primarily from the EU in terms of Brite Euram projects and from Enterprise Ireland. To give focus to my research activities, in 1997, I established the Micromechanics Reseach Unit (MICRU) as part of the Manufacturing Research Centre (MRC) at the University. This has helped give my research activities a higher profile and has assisted me in attracting external funding. To complement the micromechanics activity, I have also developed significant research activities in the broader area of computational mechanics and the use of finite elements in engineering analysis and design. Funding for this work has primarily come from local and national industries. As a result of my achievements in MICRU, I began some years ago to develop a research activity linked with the local cardiovascular medical device industry, focused on applying computational modelling and experimental testing techniques to the analysis and design of minimal invasive surgical devices. Based on these initial efforts, I was successful in obtaining significant levels of funding, from industrial and national sources, for cardiovascular medical device research. I quickly developed a keen interest in the broader Biomedical Engineering Science (BMES) area and saw great scope for application of my advanced modelling and analysis skills, in particular in terms of helping to understand the physical behaviour of biological materials, i.e., tissue and cells. I have been intimately involved in the development of the overall BMES research activity at the University over the last few years. I was part of the teams responsible for a successful 1998 HEA BMES proposal, the successful 1999 HEA PRTLI-1 proposal and the successful 2001 HEA PRTLI3 proposal. As part of PRTLI3 I was invited to join with Trinity College Dublin (TCD) as a partner in a major project in orthopaedic biomechanics, which was also successful. I was appointed a Research Director at the National Centre for Biomedical Engineering Science (NCBES) at its inception in 1999. As a natural evolution of my research activities, based on my background in micromechanics and my explorations in the area of biomedical engineering science, my research interests are currently focused on the following themes: Cardiovascular medical devices, Cardiovascular tissue mechanics, Orthopaedic biomechanics. |
Peer Reviewed Journals
| McHugh P.E., Asaro R.J., Shih C.F. (1993) 'Computational Modeling of Metal Matrix Composite Materials-I. Isothermal Deformation Patterns in Ideal Microstructures'. Acta Metallurgica et Materialia, 41 (5):1461-1476. [Details] |
| McHugh P. E., Asaro R. J. and Shih C. F. (1993) 'Computational Modeling of Metal Matrix Composite Materials-IV. Thermal Deformations'. Acta Metallurgica et Materialia, 41 (5):1501-1510. [Details] |
| McHugh P.E., Asaro R.J., Shih C.F. (1993) 'Computational Modeling of Metal Matrix Composite Materials-III. Comparisons with Phenomenological Models'. Acta Metallurgica et Materialia, 41 (5):1489-1499. [Details] |
| McHugh P.E., Asaro R.J., Shih C.F. (1993) 'Computational Modeling of Metal Matrix Composite Materials-II. Isothermal Stress-Strain Behavior'. Acta Metallurgica et Materialia, 41 (5):1477-1488. [Details] |
| McHugh, P.E., Connolly, P. (1994) 'Modelling the Thermo-Mechanical Behaviour of an Al alloy-SiC Composite - Effects of Particle Shape and Microscale Failure'. Computational Materials Science, 3 :199-206. [Details] |
| O'Grady, M., McCarthy, B., Donnellan, I., McHugh, P.E., Heslin, P. (1996) 'Vibration in an Automobile Internal Rear-View Mirror'. Key Engineering Materials, 118-119 :35-42. [Details] |
| O'Dowd, N.P., Lim, L.H., McHugh, P.E. (1996) 'Thermomechanical Modelling of Aluminium Matrix Composites'. Key Engineering Materials, 118-119 :187-192. [Details] |
| Lim, L.H., O'Dowd, N.P., McHugh, P.E. (1996) 'Computational Modelling of the Cyclic Behaviour of Aluminium and Aluminium Matrix Composites'. Computational Materials Science, 5 :187-194. [Details] |
| O'Regan, T.L., Quinn, D.F., McHugh, P.E. (1996) 'Finite Element Simulations in Metals using Remeshing'. Key Engineering Materials, 118-119 :171-178. [Details] |
| Quinn, D.F., Connolly, P.J., Howe, M.A., McHugh, P.E. (1997) 'Simulation Void Growth in WC-Co Hardmetals using Crystal Plasticity Theory'. International Journal of Mechanical Sciences, 39 (2):173-183. [Details] |
| McHugh, P.E., Mohrmann, R. (1997) 'Modelling of Creep in a Ni base Superalloy using a Single Crystal Plasticity Model'. Computational Materials Science, 9 :134-140. [Details] |
| McHugh, P. E. and Riedel, H. (1997) 'A Liquid Phase Sintering Model: Application to Si3N4 and WC-Co'. Acta Materialia, 45 (7):2995-3003. [Details] |
| O'Regan, T.L., Quinn, D.F., Howe, M.A., McHugh, P.E. (1997) 'Void Growth Simulations in Single Crystals'. Computational Mechanics, 20 :115-121. [Details] |
| Connolly, P.J., McHugh, P.E. (1999) 'Fracture Modelling of WC-Co Hardmetals using Crystal Plasticity Theory and the Gurson Model'. Fatigue and Fracture of Engineering Materials and Structures, 22 :77-86. [Details] |
| Farrissey, L., Schmauder, S., Dong, M., Soppa, E., Poech, M.H., McHugh, P.E. (1999) 'Investigation of the Strengthening of Particulate Reinforced Composites using Different Analytical and Finite Element Models'. Computational Materials Science, 15 :1-10. [Details] |
| Schmauder, S., Melander, A., McHugh, P.E., Rohde, J., Honle, S., Mintchev, O., Thuvander, A., Thoors, H., Quinn, D., Connolly, P. (1999) 'New Tool Materials with a Structural Gradient for Milling Applications'. Journal de Physique IV France, 9 :147-156. [Details] |
| Farrissey, L., Ludwig, M., McHugh, P.E., Schmauder, S. (2000) 'An atomistic study of void growth in single crystalline copper'. Computational Materials Science, 18 :102-117. [Details] |
| Bruzzi, M.S., McHugh, P.E., O'Rourke, F., Linder, T. (2001) 'Micromechanical Modelling of the Static and Cyclic Loading of an Al 2141 - SiC MMC'. International Journal of Plasticity, 17 (4):565-599. [Details] |
| Christofides, C., McHugh, P.E., Forn, A., Picas J.A. (2002) 'Wear of a thin surface coating: modelling and experimental investigations'. Computational Materials Science, 25 :61-72. [Details] |
| Bruno, G., Girardin, E., Giuliani, A., Manescu, A., Rustichelli, F., O'Donnell, B., McHugh, P. E. (2002) 'Residual stress analysis in aerospace MMC materials by neutron diffraction'. Applied Physics A - Materials Science and Processing, 74 :S1701-S1703. [Details] |
| McHugh, P. E. & Bruzzi, M. (2002) 'Methodology for modelling the small crack fatigue behaviour of aluminium alloys'. International Journal of Fatigue, 24 (10):1071-1078. [DOI] [Details] |
| Fleming, P., O'Rourke, S.C., Curtin, W., McCabe, J.P., Brennan, W., McHugh, P.E. (2003) 'Strain on the human sciatic nerve in-vivo during movement of the hip and knee'. The Journal of Bone and Joint Surgery, 85B (3):363-365. [DOI] [Details] |
| Barron, V., Lyons, E., Stenson-Cox, C,, McHugh, P. E., Pandit, A. (2003) 'Bioreactors for cardiovascular cell and tissue growth: A review'. Annals of Biomedical Engineering, 31 (9):1017-1030. [Details] |
| McHugh, P.E., Connolly, P.J. (2003) 'Micromechanical modelling of ductile crack growth in the binder phase of WC-Co'. Computational Materials Science, 27 :423-436. [DOI] [Details] |
| Bruzzi, M.S., McHugh, P.E. (2003) 'Application of closure based fatigue modelling methodology to Al-SiC MMCs'. International Journal of Fatigue, 25 :577-584. [DOI] [Details] |
| Murphy, B.P., Savage, P., McHugh, P.E., Quinn, D. (2003) 'The stress-strain behaviour of coronary stent struts is size dependent'. Annals of Biomedical Engineering, 31 (6):686-691. [DOI] [Details] |
| Coghlan, K., Barron, V., McLucas, E., O'Brien, M., Ball, M., McHugh, P.E. (2003) 'The effect of dynamic mechanical stimulation on vascular endothelial cells in vitro'. Proceedings of the 27th Annual Symposium of the Microscopical Society of Ireland, . [Details] |
| Bruzzi, M.S., McHugh, P.E. (2004) 'Micromechanical investigation of the fatigue crack growth behaviour of Al-SiC MMCs'. International Journal of Fatigue, 26 :795-804. [Details] |
| Stenson-Cox, C., Barron, V., Murphy, B.P., McHugh, P.E., Smith, T. (2004) 'Profiling the shear stress of atherosclerosis; a genomic view'. Current Genomics, 5 :287-297. [Details] |
| Bruzzi, M.S., McHugh, P.E. (2004) 'Predicting the effects of overloads on fatigue crack growth in an Al-SiC MMC using a computational model'. Journal of Engineering Materials and Technology, 126 (2):172-178. [Details] |
| McGarry, J.P., O'Donnell, B.P., McHugh, P.E., McGarry, J.G. (2004) 'Analysis of the mechanical performance of a cardiovascular stent design based on micromechanical modelling'. Computational Materials Science, 31 :421-438. [DOI] [Details] |
| Savage, P., O'Donnell, B.P., McHugh, P.E., Murphy, B.P., Quinn, D. (2004) 'Coronary stent strut size dependent stress-strain response investigated using micromechanical finite element models'. Annals of Biomedical Engineering, 32 (2):202-211. [Details] |
| McGarry, J. P., Murphy, B. P. and McHugh, P. E. (2005) 'Computational mechanics modelling of cell-substrate contact during cyclic substrate deformation'. Journal of the Mechanics and Physics of Solids, 53 (12):2597-2637. [Details] |
| Tyndyk, M.A., Barron, V., McHugh, P.E. (2005) 'Effect of osteoporosis on the biomechanics of the thoracolumbar spine: Finite Element Study'. EUROPEAN CELLS AND MATERIALS, 10 (3). [Details] |
| Albertini, G., Girardin, E., Giuliani, A., Ilie, D.E., O'Donnell B.P., McGarry, J.P., McHugh, P.E. (2005) 'Micromechanical Finite element simulation and experimental determination of residual stresses after extrusion process in metal matrix composites'. ADVANCED COMPOSITES LETTERS, 14 (4). [Details] |
| Farrissey, L.M., McHugh, P.E. (2005) 'Determination of elastic and plastic material properties using indentation: Development of method and application to a thin surface coating'. MATERIALS SCIENCE AND ENGINEERING, 399 :254-266. [DOI] [Details] |
| Lohfeld, S., Barron, V., McHugh, P.E. (2005) 'Biomodels of Bone: A Review'. Annals of Biomedical Engineering, 33 (10):1295-1311. [Details] |
| Weldon, L.M., McHugh, P E., Carroll W., Costello, E., O'Bradaigh C.M. (2005) 'The influence of passivation and electropolishing on the performance of medical grade stainless steels in static and fatigue loading'. Journal of Materials Science: Materials in Medicine, 16 (2):107-117. [Details] |
| Connolley, T., McHugh, P. E. and Bruzzi, M. S. (2005) 'A review of deformation and fatigue of metals at small size scales'. Fatigue and Fracture of Engineering Materials and Structures, 28 (12):1119-1152. [Details] |
| Bruzzi, M.S., McHugh, P.E. (2005) 'Micromechanical modelling of the static loading of an Al 359-SiC MMC'. Journal of Engineering Materials and Technology, 127 (1):106-118. [Details] |
| Breen, L., McHugh, P. E., McCormack, B. A., Muir, G., Quinlan, N., Heraty, K., Murphy, B.P. (2006) 'Development of a novel bioreactor to apply shear stress and tensile strain simultaneously to cell monolayers'. Review of Scientific Instruments, 77 . [Details] |
| Mullins, L.P., Bruzzi, M.S., McHugh, P.E. (2006) 'Microcrack growth in cortical bone using indentation fracture'. JOURNAL OF BIOMECHANICS, 39 (1). [Details] |
| O'Cearbhaill, E., Barron, V. and McHugh, P. E. (2006) 'Characterisation of a collagen membrane for its potential use in cardiovascular tissue engineering applications'. Journal of Materials Science: Materials in Medicine, 17 (3):195-201. [Details] |
| You, X., Connolley, T., McHugh, P.E., Cuddy, H., Motz, C. (2006) 'A Combined Experimental and Computational Study of Deformation in Grains of Biomedical Grade 316LVM Stainless Steel'. ACTA MATERIALIA, 54 :4825-4840. [DOI] [Details] |
| Murphy, B.P., Cuddy. H., Harewood, F., Connolley, T., McHugh, P.E. (2006) 'The influence of grain size on the ductility of micro-scale stainless steel stent struts'. Journal of Materials Science: Materials in Medicine, 17 (1):1-6. [DOI] [Details] |
| Harewood, F., McHugh, P.E. (2006) 'Investigation of Finite Element Mesh Independence in Rate Dependent Materials'. Computational Materials Science, 37 :442-453. [DOI] [Details] |
| Punchard, M.A., Stenson-Cox, C., O'Cearbhaill, E., Lyons, E., Gundy, S., Murphy, L., Pandit, A., McHugh, P.E., Barron V. (2007) 'Endothelial Cell Response to Biomechanical Forces under Simulated Vascular Loading Conditions'. Journal of Biomechanics, 40 (14):3146-3154. [Details] |
| Caulfield, B; McHugh, PE; Lohfeld, S (2007) 'Dependence of mechanical properties of polyamide components on build parameters in the SLS process'. Journal Of Materials Processing Technology, 182 :477-488. [DOI] [Details] |
| O'Cearbhaill, E.D., Punchard, M.A., Murphy, M., Barry, F., McHugh, P.E., Barron, V. (2007) 'Response of Mesenchymal Stem Cells to the Biomechanical Environment of the Endothelium on a Flexible Tubular Silicone Substrate'. Biomaterials, 29 :1610-1619. [Details] |
| Mullins, L., McGarry, J.P., Bruzzi, M., McHugh, P.E. (2007) 'Micromechanical modelling of cortical bone'. Computer Methods in Biomechanics and Biomedical Engineering, 10 (3):159-169. [Details] |
| Harewood, F., McHugh, P.E. (2007) 'Modelling of size dependent failure in cardiovascular stent struts under tension and bending'. Annals of Biomedical Engineering, 35 (9):1539-1553. [DOI] [Details] |
| Lohfeld, S; McHugh, PE; Serban, D; Boyle, D; O'Donnell, G; Peckitt, N (2007) 'Engineering assisted surgery: A route for digital design and manufacturing of customized maxillofacial implants'. Journal Of Materials Processing Technology, 183 :333-338. [DOI] [Details] |
| Mullins L.P., Bruzzi, M.S., McHugh, P.E. (2007) 'Measurement of the microstructural fracture toughness of cortical bone using indentation fracture'. Journal of Biomechanics, 40 (14):3285-3288. [Details] |
| Harewood, F., McHugh, P.E. (2007) 'Comparison of the Implicit and Explicit Finite Element Methods using Crystal Plasticity'. Computational Materials Science, 39 (2):481-494. [DOI] [Details] |
| McDonnell, P., McHugh, P.E., O'Mahoney, D. (2007) 'Vertebral Osteoporosis and Trabecular Bone Quality'. Annals of Biomedical Engineering, 35 (2):170-189. [Details] |
| Barron, V., Brougham, C., Coghlan, K., McLucas, E., O'Mahoney, D., Stenson-Cox, C., McHugh, P. E. (2007) 'The effect of physiological cyclic stretch on the cell morphology, cell orientation and protein expression of endothelial cells'. Journal of Materials Science: Materials in Medicine, 8 (10):1973-1981. [Details] |
| Connolley, T., Nash, D., Buffiere, J-Y., McHugh, P.E. (2007) 'X-ray micro-tomography of a coronary stent deployed in a model artery'. Medical Engineering and Physics, 29 (10):1132-1141. [DOI] [Details] |
| Ilie, D.E., O'Donnell, B.P., McGarry, J.P., McHugh, P.E. (2007) 'Computational Modelling of the Extrusion of an Al-SiC Metal Matrix Composite using Macroscale and Microscale Methods'. Journal of Strain Analysis for Engineering Design, 42 :237-252. [Details] |
| Flaherty, B., McGarry, J. P., McHugh, P.E. (2007) 'Mathematical models of cell motility'. Cell Biochemistry and Biophysics, 49 (1):14-28. [DOI] [Details] |
| Tyndyk, M., McHugh, P.E., Barron, V., O'Mahoney, D. (2007) 'Generation of a finite element model of the thoracolumbar spine'. Acta of Bioengineering and Biomechanics, 9 (1):35-46. [Details] |
| McGarry, J.P., O'Donnell, B., McHugh, P.E., O'Cearbhaill, E., McMeeking, R.M. (2007) 'Computational examination of the effect of material inhomogenity on the necking of stent struts in tensile loading'. Journal of Applied Mechanics, 74 :978-989. [Details] |
| Riordan, C., Mahajan, A., Brennan, W., Murphy, B.P., Regan, P., McHugh, P.E. (2007) 'Biomechanical study of the FDP Demi-Tendon - A new technique for ZoneI/II Flexor tendon grafting'. JOURNAL OF HAND SURGERY, . [Details] |
| Thakral, R., Kaar, K., McHugh, P.E., Brennan, W., Lalor, S. (2007) 'Weber B lateral malleolar fracture and inter fragmentary screw placement'. EJOST - European Journal of Orthopaedic Surgery and Traumatology, 17 (5):461-464. [DOI] [Details] |
| McGarry, J.P., McHugh, P.E. (2008) 'Modelling of in-vitro chondrocyte detachment'. Journal of the Mechanics and Physics of Solids, 56 (4):1554-1565. [DOI] [Details] |
| Mullins, L. P., Bruzzi, M. S., and McHugh, P. E. (2008) 'Authors' response to comments on Measurement of the microstructural fracture toughness of cortical bone using indentation fracture'. Journal of Biomechanics, 41 (11):2602-2603. [Details] |
| Stops. A.J.F., McMahon, L.A., O'Mahoney, D., Prendergast, P., McHugh, P.E. (2008) 'A Finite Element Prediction of Strain on Cells in a Highly Porous Collagen-Glycosaminoglycan Scaffold'. ASME Journal of Biomechanical Engineering, 130 (6). [Details] |
| O'Halloran, A., O'Malley, F., McHugh, P. (2008) 'A review on dielectric elastomer actuators, technology, applications, and challenges'. Journal of Applied Physics, 104 (7). [Details] |
| McDonnell, P., Liebschner, M.A.K., Tawackoli, W., McHugh, P.E. (2009) 'Vibration testing of trabecular bone architectures using rapid prototype models'. Medical Engineering and Physics, 31 (1):108-115. [DOI] [Details] |
| Mullins, L.P., Bruzzi, M.S., McHugh, P.E. (2009) 'Calibration of a Constitutive Model for the Post-Yield Behaviour of Cortical bone'. Journal of the Mechanical Behaviour of Biomedical Materials, 2 (5):460-470. [DOI] [Details] |
| Cahill, S., Lohfeld, S., McHugh, P.E. (2009) 'Finite element predictions compared to experimental results for the effective modulus of bone tissue engineering scaffolds fabricated by Selective Laser Sintering'. Journal of Materials Science: Materials in Medicine, 20 :1255-1262. [DOI] [Details] |
| Breen, L., McHugh, P.E., Murphy, B.P. (2009) 'Multi-axial mechanical stimulation of HUVECs demonstrates that combined loading is not equivalent to the superposition of individual wall shear stress and tensile hoop stress components'. ASME Journal of Biomechanical Engineering, 131 (8):1-11. [Details] |
| Mullins, L.M., Sassi, V., McHugh, P.E., Bruzzi, M.S. (2009) 'Differences in the crack resistance of trabecular, osteonal and interstitial bone'. Annals of Biomedical Engineering, 37 (12):2574-2582. [DOI] [Details] |
| Punchard, M.A., O'Cearbhaill, E.D., Mackle, J.N., McHugh, P.E., Smith, T.J., Stenson-Cox, C., Barron, V. (2009) 'Evaluation of human endothelial cells post stent deployment in a cardiovascular simulator in-vitro'. Annals of Biomedical Engineering, 37 (7):1322-1330. [DOI] [Details] |
| Hopkins, C., McHugh, P.E., McGarry, J.P. (2010) 'Computational investigation of the delamination of polymer coatings during stent deployment'. Annals of Biomedical Engineering, 38 (7):2263-2273. [DOI] [Details] |
| O'Cearbhaill, E.D., Murphy, M., Barry, F., McHugh, P.E., Barron, V. (2010) 'Behaviour of Human Mesenchymal Stem Cells in Fibrin-based Vascular Tissue Engineering Constructs'. Annals of Biomedical Engineering, 38 (3):649-657. [DOI] [Details] |
| Harrison, N.M., McHugh, P.E. (2010) 'Comparison of trabecular bone behaviour in core and whole bone samples using high resolution modelling of a vertebral body'. Biomechanics and Modelling in Mechanobiology, 9 (4):469-480. [DOI] [Details] |
| P. McDonnell, Harrison, N.M., Lohfeld, S., Kennedy, O., Zhang, Y. and McHugh, P.E. (2010) 'Investigation of the mechanical interaction of the trabecular core with an external shell using rapid prototype and finite element models'. Journal of the Mechanical Behaviour of Biomedical Materials, 3 :63-76. [Details] |
| McDonnell, P., Harrison, N.M., McHugh, P.E. (2010) 'Investigation of the Failure Behaviour of Vertebral Trabecular Architectures under Pure Compression and Wedge Action Loading Conditions'. Medical Engineering and Physics, 32 (6):569-576. [DOI] [Details] |
| Stops. A.J.F., Heraty, K.B., Browne, M., O'Brien, F.J., McHugh, P.E. (2010) 'A prediction of cell differentiation and proliferation within a collagen-glycosaminoglycan scaffold subjected to mechanical strain and perfusive fluid flow'. Journal of Biomechanics, 43 (4):618-626. [DOI] [Details] |
| Stops. A.J.F., Harrison, N.M., Haugh, M.G., O'Brien, F.J., McHugh, P.E. (2010) 'Local and regional mechanical characterisation of a collagen-glycosaminoglycan scaffold using high-resolution finite element analysis'. Journal of the Mechanical Behaviour of Biomedical Materials, 3 :292-302. [Details] |
| McDonnell, P., Harrison, N.M., Liebschner, M.A.K., McHugh, P.E. 'Simulation of vertebral trabecular bone loss using voxel finite element analysis'. Journal of Biomechanics, 42 :2789-2796. [Details] |
| Breen, L., McHugh, P.E., Murphy, B.P. 'The experimental verification and validation of a custom bioreactor: The experimental application of carotid artery athero-prone and athero-protective wall shear stress and tensile strain to HUVECs'. Annals of Biomedical Engineering, 38 (5):1880-1892. [Details] |
Conference Publications
| MCHUGH, PE et al. (1994) MODELING THE THERMOMECHANICAL BEHAVIOR OF AN AL ALLOY-SICP COMPOSITE EFFECTS OF PARTICLE-SHAPE AND MICROSCALE FRACTURE COMPUTATIONAL MATERIALS SCIENCE , pp.199-206 [Details] |
| MCHUGH, PE et al. (1997) Modelling of creep in a Ni base superalloy using a single crystal plasticity model COMPUTATIONAL MATERIALS SCIENCE , pp.134-140 [Details] |
| MCHUGH, PE et al. (2004) Introduction to crystal plasticity theory Mechanics of Microstructured Materials , pp.125-171 [Details] |
Conference Paper
| McHugh, P.E., Asaro, R.J., Shih, C.F., Varias, A.G. (1989) Computational Modeling of Metal Matrix Composite Materials. Conference Paper [Details] |
| Varias, A.G., O'Dowd, N.P., McHugh, P.E., Shih, C.F. (1990) Computational Modeling of Interfacial Failure. Conference Paper [Details] |
| McHugh, P.E., Asaro, R.J., Shih, C.F. (1990) Computational modelling of metal matrix composite materials. Conference Paper [Details] |
| McHugh, P.E., Asaro, R.J., Shih, C.F. (1991) Computational Modeling of Al-Cu Matrix, SiC Reinforced Composite Materials. Conference Paper [Details] |
| McHugh, P.E., Hoade, J. (1993) Modelling the Thermo-Mechanical Behaviour of an Al alloy-SiC Composite. Conference Paper [Details] |
| McHugh, P.E. (1993) Modelling the Thermo-Mechanical behaviour of an Al alloy - SiCp Composite. Conference Paper [Details] |
| Connolly, P., Quinn, D., Howe, M., McHugh, P.E. (1995) Investigation of Failure in Functionally Graded WC-Co Hardmetals using Crystal Plasticity Theory. Conference Paper [Details] |
| McHugh, P.E. (1995) Crystal plasticity theory and its applications to the modelling of microstructural deformation in metals and metal matrix composites. Conference Paper [Details] |
| Quinn, D. F., Connolly, P.J., O'Regan, T.L., Howe, M.A., McHugh, P.E. (1995) Simulation of Co Binder Failure in WC-Co Hardmetals. Conference Paper [Details] |
| Quinn, D. F., Howe, M.A., McHugh, P.E. (1995) Simulation Void Growth in WC-Co Hardmetals using Crystal Plasticity Theory. Conference Paper [Details] |
| McHugh, P.E. (1996) Crystal plasticity theory. Conference Paper [Details] |
| Quinn, D., McHugh, P.E. (1996) Modelling void growth in metals. Conference Paper [Details] |
| McHugh, P.E., Riedel, H. (1997) A computational model for liquid phase sintering. Conference Paper [Details] |
| McCarthy, B.B., McHugh, P.E., Heslin, P.E., O'Grady, M.P. (1997) Development of a finite element software design aid for automotive rear-view mirrors. Development of a finite element software design aid for automotive rear-view mirrors. Conference Paper [Details] |
| Bruzzi, M., Eberhardt, M., McHugh, P.E. (1997) Micro-macro modelling of the mechanical behaviour of MMCs during cyclic loading. Conference Paper [Details] |
| Quinn, D.F., Connolly, P.J., McHugh, P.E. (1997) 'Ductile Failure by Void Growth in Single Crystals Modelled using Crystal Plasticity Theory. Conference Paper [Details] |
| McCarthy, B., McHugh, P.E., Heslin, P., O'Grady, M. (1997) Development of a finite element software design aid for automobile rear-view mirrors: investigation of material damping. Development of a finite element software design aid for automobile rear-view mirrors: investigation of material damping. Conference Paper [Details] |
| Connolly, P.J., McHugh, P.E. (1997) Fracture modelling in metal-ceramic composites using the Gurson model and crystal plasticity theory. Conference Paper [Details] |
| Gilvarry, M., O'Dowd, N.P., McHugh, P.E. (1998) Examination of Mechanical Behaviour of a High Strength Aluminium Alloy in Static and Fatigue Loading. Conference Paper [Details] |
| Cunniffe, B., McHugh, P.E., O'Bradaigh, C.M. (1998) Finite element analysis of catheter navigation through tortuous body vessels. Conference Paper [Details] |
| Connolly, P.J., McHugh, P.E. (1998) Modelling of crack growth in WC-Co. Conference Paper [Details] |
| Schmauder, S., Melander, A., McHugh, P.E., Rohde, J., Honle, S., Mintchev, O., Thuvander, A., Thoors, H., Quinn, D., Connolly, P. (1998) New Tool Materials with a Structural Gradient for Milling Applications. Conference Paper [Details] |
| O'Sullivan, M., Mullarkey, T.P., McNamara, J.F., McHugh, P.E. (1998) Behaviour and control of the axial strain in finite rotations of flexible rods. Conference Paper [Details] |
| Bruzzi, M.S., McHugh, P.E. (1998) Micromechanical modelling of the tensile behaviour of an Al-SiC MMC. Conference Paper [Details] |
| Farrissey, L., Ludwig, M., McHugh, P.E., Schmauder, S. (1998) An atomistic study of single crystal void growth. Conference Paper [Details] |
| Bruzzi, M.S., McHugh, P.E. (1999) Modelling the Mechanical Behaviour of MMCs in Static Loading. Conference Paper [Details] |
| Connolly, P.J., McHugh, P.E. (1999) Computational Modelling of crack growth in WC-Co: Effects of Microscale Parameters. Conference Paper [Details] |
| Bruzzi, M.S., McHugh, P.E. (1999) The Computational Modelling of the Short Crack Fatigue Behaviour of Al-SiC MMCs. Conference Paper [Details] |
| Cunniffe, B., McHugh, P. E., O'Bradaigh, C M. (1999) FEM analysis of catheter navigation through coronary arteries. Conference Paper [Details] |
| O'Dowd, N.P., Tang, W.C., Busso, E.P., McHugh, P.E. (1999) Modelling of Deformation and Failure of Metal/Ceramic Composites. Conference Paper [Details] |
| Cunningham, J., McHugh, P.E. (1999) Development of a finite element software design aid for automotive rear-view mirrors. Development of a finite element software design aid for automotive rear-view mirrors. Conference Paper [Details] |
| McHugh, P.E. (1999) Some applications of computational modelling in biomedical engineering science. Conference Paper [Details] |
| Bruzzi, M.S., McHugh, P.E. (1999) The performance of micromechanical models in predicting the mechanical behaviour of MMCs. Conference Paper [Details] |
| O'Reilly, D., McHugh, P.E. (2000) Modelling the relative motion and contact between gearbox components. Conference Paper [Details] |
| Christofides, C., McHugh, P.E. (2000) Modelling of deformation and wear of coated metals during pin on disc tests. Conference Paper [Details] |
| Farrissey, L., McHugh, P.E. (2000) Use of finite element methods to determine the mechanical properties of thin surface coatings from nano-indentation tests. Conference Paper [Details] |
| McHugh, P.E. (2000) The National Centre for Biomedical Engineering Science. Conference Paper [Details] |
| Bruzzi, M.S., McHugh, P.E. (2000) Methodology for Modelling the Short Crack Fatigue Behaviour of Al-SiC MMCs. Conference Paper [Details] |
| McGarry, J.P., McHugh, P.E., McMeeking, R. (2000) Computational modelling of the mechanical behaviour and wear performance of RPS coatings. Conference Paper [Details] |
| O'Donnell, B., McHugh, P.E. (2000) A numerical investigation into the effects of clustering on interfacial debonding of particulate reinforced metal matrix composites. Conference Paper [Details] |
| O'Reilly, D., McHugh, P.E. (2000) Finite element modelling of relative surface motion of cone-synchroniser friction interface in heavy automotive transmissions. Conference Paper [Details] |
| McHugh, P.E. (2000) Applications of finite element modelling in biomedical engineering. Conference Paper [Details] |
| Cunniffe, B., McHugh, P.E., O'Bradaigh, C.M. (2000) Investigation of the significance of viscoelastic effects in the performance of minimally invasive surgical devices. Conference Paper [Details] |
| Weldon, L., McHugh, P.E., O'Bradaigh C.M. (2000) Assessment of the effects of surface passivation on the mechanical properties of 316L stainless steel. Conference Paper [Details] |
| McGarry, J.P., McHugh, P.E. (2000) Modelling the Mechanical Performance of Thermal Spray MMC Coatings. Conference Paper [Details] |
| Tabering, B., Pippan, P., Bruzzi, M.S., McHugh, P.E., Foulquier, J., Rapoport, A., Fedrigoni, G.P., Powell, P. M., Cook, R., Forn, A., Martin, E., Fiori, F., Rustichelli, F. (2000) Modelling of In-Service Fatigue Performance of Particle Reinforced Aluminium Alloys. Conference Paper [Details] |
| McHugh, P.E., O'Bradaigh, C.M., Molloy, P., Eaton, J.A., Nolan, P.J., Quinlan, N. (2000) Biomedical Engineering Research. Conference Paper [Details] |
| Pearse, K., McHugh, P.E., O'Bradaigh, C.M. (2000) Computational modelling of the deformation of 316L stainless steel in stent applications. Conference Paper [Details] |
| McNamara, J.F., McHugh, P.E. (2000) Development of a biomedical engineering programme to complement industrial expansion in Ireland. Development of a biomedical engineering programme to complement industrial expansion in Ireland. Conference Paper [Details] |
| O'Rourke, S., McHugh, P.E., Carroll, W., Cunningham, D. (2000) Development of a new ceramic coating technique for the production of tailored coatings on metals and other materials. Development of a new ceramic coating technique for the production of tailored coatings on metals and other materials. Conference Paper [Details] |
| Bruno, G., Girardin, E., Guiliani, A., Manescu, A., Rustichelli, F., O'Donnell, B., McHugh, P.E. (2001) Residual stress analysis in aerospace MMC materials by neutron diffraction. Conference Paper [Details] |
| McHugh, P.E. (2001) Biomedical Engineering Science in NUI, Galway. NUI, Galway: Conference Paper [Details] |
| Tyndyk, M., McHugh, P.E. (2001) Computational micromechanical and macromechanical modelling of bone: application to lumbar spine. Conference Paper [Details] |
| Foagrassy, P., McHugh. P.E., McGarry, J.P., Voda, M., Lesage, J., Mesmacque, G. (2001) Residual stress analysis on metallic-ceramic functionally graded coatings. Conference Paper [Details] |
| O'Rourke, S.C., McHugh, P.E., Carroll, W.M., Cunningham, D., Rushe, N., Healy, S. (2001) Experimental techniques for the determination of the mechanical characteristics of an ultra-thin ceramic coating for use on metallic and other materials: preliminary results. Conference Paper [Details] |
| Fleming, P., O'Rourke, S.C., Curtin, W., McCabe, J.P., Brennan, W., McHugh, P.E. (2001) Tension on the sciatic nerve during total hip replacement - an in vivo study. Conference Paper [Details] |
| Caulfield, B.P., McHugh, P.E. (2002) Customising the customised implant. Conference Paper [Details] |
| Tyndyk, M., McHugh, P.E. (2002) Modelling of lumbar spine: Model generation methodologies and case study applications. Conference Paper [Details] |
| Savage, P., O'Donnell, B.P., Murphy, B.P., McHugh, P.E. (2002) The finite element analysis of 316L stainless steel wires to simulate experimental tensile behaviour. Conference Paper [Details] |
| Savage, P., O'Donnell, B.P., McHugh, P.E. (2002) The finite element analysis of 316L stainless steel wires to simulate experimental behaviour. Conference Paper [Details] |
| Caulfield, B.P,. McHugh, P.E. (2002) Characterisation of SLS produced implant materials. Conference Paper [Details] |
| Murphy, B.P., Bruzzi, M.S., Savage. P., Quinn, D.F., McHugh, P.E. (2002) The tensile behaviour of stainless steel coronary stent wires is highly dependent on strut size. Conference Paper [Details] |
| Gachon, C., Delassus, P., McHugh, P.E. (2002) Influence of the manufacturing path on the mechanical behaviour of medical devices such as stents. Conference Paper [Details] |
| Tyndyk, M., McHugh, P.E. (2002) Finite element modelling of the lumbar spine: Model generation methodologies and case study applications. Conference Paper [Details] |
| Cunningham, D., Carroll, W., Rushe, N., Healy, S., McHugh, P.E., Murphy, B. (2002) The analysis of tin oxide films obtained by a novel deposition technique. Conference Paper [Details] |
| Riordan, C., Mahajan, A., Brennan, W., Murphy, B.P., Regan, P., McHugh, P.E. (2002) Biomechanical study of the FDP Demi-Tendon - A new technique for ZoneI/II Flexor tendon grafting. Conference Paper [Details] |
| Murphy, B.P., Savage, P., O'Donnell, B.P., McHugh, P.E. (2002) Computational modelling and experimental testing to determine the constitutive and failure behaviour of 316L stainless steel for stent applications. Conference Paper [Details] |
| Farrissey, L., McHugh, P.E. (2002) The application of computational micromechanics to determine mechanical properties of materials from nano-indentation tests and to predict wear performance. Conference Paper [Details] |
| Harrison, N.M., McHugh, P.E. (2003) Trabecular bone computer model generation methodologies. Conference Paper [Details] |
| Cuddy, H., Murphy, B., McHugh, P.E., Quinn, D. (2003) Experimental analysis of the influence of grain size on the mechanical properties of thin 316L stainless steel wires for vascular stent applications. Conference Paper [Details] |
| Tyndyk, M., McHugh, P.E. (2003) Modelling and numerical analysis of the stress distribution of the lumbar vertebra. Conference Paper [Details] |
| Breen, L., Murphy, B.P., McHugh, P.E. (2003) The design of a test fixture to investigate the effects of tensile ans simultaneous shear forces on endothelial cells. Conference Paper [Details] |
| Barron, V., McHugh, P.E. (2003) The effect of mechanical stimulation on cell signalling and gene expression of vascular smooth muscle cells. Conference Paper [Details] |
| Ilie, D., McHugh, P.E. (2003) Modelling the mechanical properties size effect for cardiovascular stents using the finite element method and strain gradient plasticity. Conference Paper [Details] |
| Coghlan, K., Barron, V., McLucas, E., O'Brien, M., Ball, M., McHugh, P.E. (2003) The effect of dynamic mechanical stimulation on vascular endothelial cells in vitro. Conference Paper [Details] |
| McGarry, J. P. and McHugh, P. E. (2003) Computational analysis of the in-service mechanical behaviour of coated cardiovascular stents. Conference Paper [Details] |
| Thakral, R., Kaar, K, McHugh, P. E., Brennan, W., Lawlor, S. & Black, A. (2003) 'Weber B' lateral malleolar fracture and inter-fragmentary screw placement. Conference Paper [Details] |
| Connolley, T., Cuddy, H., Bruzzi, M., McHugh, P E. (2003) Metallography of 316L stainless steel fine wires and tubes used for cardiovascular implants. Conference Paper [Details] |
| Savage, P., Murphy, B.P., Quinn, D.F., McHugh, P.E. (2003) Finite element analysis of 316L stainless steel stent struts to simulate different loading conditions. Conference Paper [Details] |
| Lohfeld, S., Serban, D., Boyle, D., McHugh, P.E., Peckitt, N. (2003) Relieving design and manufacturing of maxillofacial prostheses. Conference Paper [Details] |
| Gachon, C., Delassus, P., McHugh, P.E. (2003) Influence of the dimensions on the mechanical behaviour of stents. Conference Paper [Details] |
| Caulfield, B.P., McHugh, P.E. (2003) Selective laser sintering systems to directly manufacture customised implants. Conference Paper [Details] |
| Breen, L. T., Murphy, B. P. and McHugh, P. E. (2003) Experimental rig to apply pulsatile tensile and shear forces to endothelial cells. Conference Paper [Details] |
| Serban, D., Boyle, D., Lohfeld, S., McHugh, P.E., Peckitt, N. (2003) Design and manufacturing of customised maxillofacial prostheses. Conference Paper [Details] |
| Coghlan, K., O'Cearbhaill, E., Barron, V., McLucas, E., O'Brien, M., Ball, M.D., Stenson-Cox, C., McHugh, P.E. (2004) Mechano-Biological Interactions of Endothelial Cells. Conference Paper [Details] |
| Tyndyk, M.A., Barron V., McHugh, P.E. (2004) Load transfer mechanism within the lumbar vertebra. Conference Paper [Details] |
| Murphy, B.P., Breen, A., McHugh, P.E. (2004) Is there a modulus mismatch between the two components of PMMA bone cement. Conference Paper [Details] |
| Breen, L.T., Murphy, B.P., McHugh, P.E. (2004) Experimental rig to apply pulsatile tensile and shear forces to endothelial cells. Conference Paper [Details] |
| Flaherty, B., McHugh, P.E. (2004) Endothelial cell morphological changes under mechanical load: Modelling and experimentation. Conference Paper [Details] |
| O'Cearbhaill E.D., Murphy, L., Barron, V., McHugh, P.E. (2004) Design of a mechanical fixation device to test the mechanical properties of collagen scaffolds. Conference Paper [Details] |
| Harewood, F., McHugh, P.E. (2004) Comparison of finite element methods using crystal plasticity to model stent mechanical performance. Conference Paper [Details] |
| O'Cearbhaill E.D., Murphy, L., Barron, V., McHugh, P.E. (2004) Characterisation of a Collagen Membrane as a Potential Cardiovascular Tissue Engineering Scaffold. Conference Paper [Details] |
| O'Shea, M., Cuddy, H., Connolley, T., McHugh, P.E. (2004) A micro-tensile testing stage for optical and scanning electron microscopy. Conference Paper [Details] |
| Lohfeld S., McHugh, P.E. (2004) Accuracy and size limits of biomodels manufactured by selective laser sintering. Conference Paper [Details] |
| Mullins, L., Bruzzi, M.S., McHugh P.E. (2004) Micromechanical finite element modelling of local stress fields in cortical bone. Conference Paper [Details] |
| Harewood, F., McHugh, P.E. (2004) Microscale modelling of the mechanical behaviour of cardiovascular stents. Conference Paper [Details] |
| Brougham C., Coghlan, K., Murphy, L., Stenson-Cox, C., Barron, V., McHugh, P.E. (2004) Towards a Tissue Engineered Coronary Artery. Conference Paper [Details] |
| You, X., McHugh, P.E. (2004) 3D micromechanical finite element modelling of cardiovascular stent struts. Conference Paper [Details] |
| Ilie, D., McHugh, P.E. (2004) Capturing the mechanical properties size effect in vascular strents using a non-localised constitutive theory. Conference Paper [Details] |
| McGarry, J.P., Murphy, B.P., McHugh, P.E. (2004) Computational modelling of cell-substrate contact during cyclic mechanical substrate deformation. Conference Paper [Details] |
| Connolley, T., Bruzzi, M.S., McHugh, P.E. (2004) Fatigue analysis of cardiovascular implants. Conference Paper [Details] |
| Harrison, N.M., McHugh, P.E. (2004) Microscale computational modelling methodologies of bone. Conference Paper [Details] |
| O'Cearbhaill, E.D., Barron, V., McHugh, P.E. (2004) The biological response of endothelial cells seeded on surface treated vascular graft materials. Conference Paper [Details] |
| Cuddy, H., Connolley, T., Murphy, B.P., Bruzzi, M.S., McHugh, P.E., Quinn, D.F. (2004) Experimental analysis of size impact on mechanical properties of fine wires for vascular implants. Conference Paper [Details] |
| Connolley, T., Donnelly, E., Bruzzi, M.S., McHugh, P.E. (2004) Fatigue of small metallic structures - is there a size effect?. Conference Paper [Details] |
| Donnelly, E., Connolley, T., Bruzzi, M. S. and McHugh, P. E. (2004) Finite element comparison of performance related characteristics of cardiovascular stents. Conference Paper [Details] |
| Cuddy, H., Connolley, T., McHugh, P.E. (2004) In-situ strain mapping and orientation image microscopy of metal deformation. Conference Paper [Details] |
| Brougham, C., Coghlan, K., Barron, V., McHugh, P.E. (2004) Mechano-biological interactions of endothelial cells. Conference Paper [Details] |
| Breen, L.T., McHugh, P.E., Muir, G., McCormack, B.A.O., Murphy, B.P. (2004) The design of an experimental rig to simultaneously apply tensile and shear forces to endothelial cells. Conference Paper [Details] |
| Harrison, N.M., McHugh, P.E. (2004) Trabecular bone Computer Model Generation Methodologies. Conference Paper [Details] |
| Harewood, F., McHugh, P.E. (2004) Micromechanics based FE modelling of stents. Conference Paper [Details] |
| You, X., McHugh, P.E., Dowling, D. (2004) Microscale modelling of the wear behaviour of thin self-lubricating coatings. Conference Paper [Details] |
| Breen, L.T., McHugh, P.E., Muir, G., McCormack, B.A.O., Murphy, B.P. (2004) The design of a test fixture to investigate the effects of tensile and simultaneous shear forces on endothelial cells. Conference Paper [Details] |
| McGarry, J.P., Murphy, B.P., McHugh, P.E. (2004) Development of a cohesive zone model to simulate cellular attachment to its local environment. Development of a cohesive zone model to simulate cellular attachment to its local environment. Conference Paper [Details] |
| Ilie, D., McHugh, P.E. (2004) Representing the effects of size scale on mechanical performance of metals using a non-localised constitutive law: theory and application. Conference Paper [Details] |
| Harrison, N., McHugh, P.E. (2004) Trabecular bone computer model generation methodologies. Conference Paper [Details] |
| Tyndyk, M.A., Barron V., McHugh, P.E. (2004) Reconstruction and modelling of a detailed three dimensional FE model of the whole lumbar spine. Conference Paper [Details] |
| McGarry, J.P., Murphy, B.P., McHugh, P.E. (2004) Prediction of changes in cell morphology and adhesion using a 3D cohesive zone model. Conference Paper [Details] |
| Donnelly, E.W., Connolley, T., Bruzzi, M.S., McHugh, P.E. (2004) Modelling the post-deployment stress states in vascular stents. Conference Paper [Details] |
| Mullins, L., Bruzzi, M.S., McHugh P.E. (2004) Microstructural investigation of local stress fields and material properties of cortical bone using FEA. Conference Paper [Details] |
| Breen, L.T., Murphy, B.P., McHugh, P.E. (2005) The development of a unique bioreactor to simultaneously apply pulsatile and reversible shear and tensile forces to a monolayer of endothelial cells. Conference Paper [Details] |
| Flaherty, B., Murphy, B.P., McHugh, P E. (2005) Development of a continuum mechanics model to predict cell motility. Development of a continuum mechanics model to predict cell motility. Conference Paper [Details] |
| McGarry, J.P., Murphy, B.P., McHugh, P.E. (2005) Computational investigation of the effect of cell spreading on cell-adhesion. Conference Paper [Details] |
| McGarry, J.P., McHugh, P.E. (2005) Computational analysis of in-vitro adherent cell behaviour. Conference Paper [Details] |
| Harrison, N. and McHugh, P. E. (2005) Trabecular bone computer model generation methodologies. Conference Paper [Details] |
| You, X., McHugh, P.E. (2005) Microscale modelling of the wear behaviour of thin self-lubricating coatings. Conference Paper [Details] |
| Tyndyk, M.A., Barron V., McHugh, P.E. (2005) Assessment on SLS fabricated scaffold for bone tissue engineering. Conference Paper [Details] |
| Breen, L.T., Murphy, B.P., McHugh, P.E. (2005) Novel bioreactor: cell stretch and wall shear stress. Conference Paper [Details] |
| Flaherty, B. and McHugh, P. E. (2005) A continuum finite element model predicting cell motility. Conference Paper [Details] |
| Harrison, N.M., O'Mahoney, D., McHugh, P.E. (2005) Automated finite element voxel mesh generation. Conference Paper [Details] |
| McGarry, J.P., McHugh, P.E. (2005) Computational analysis of the mechanical behaviour of coated cardiovascular stents . Proceedings of Plasticity’05; The International Symposium on Plasticity and its Current Applications. Kauai, USA: Conference Paper [Details] |
| Breen, L.T., Murphy, B.P., McHugh, P.E. (2005) Novel Vascular Cell Culture Bioreactor. Conference Paper [Details] |
| Mullins, L., Bruzzi, M.S., McHugh P.E. (2005) The effect of microstrucutre on the mechanical properties of cortical bone. Conference Paper [Details] |
| Harewood, F., McHugh, P.E. (2005) Microscale modelling of the mechanical behaviour of cardiovascular stents. Conference Paper [Details] |
| Ilie, D.E., Connolley, T., McHugh, P.E. (2005) Representing the effect of size scale on mechanical performance of metals using a non-localised constitutive law. Conference Paper [Details] |
| Tyndyk, M.A., Barron, V., O'Mahoney, D., McHugh, P.E. (2005) Effect of disc degeneration on the biomechanics of the thoracolumbar spine. Conference Paper [Details] |
| Coghlan, K.M., McHugh, P.E. (2005) Development of a microstructural computational cell model. Development of a microstructural computational cell model. Conference Paper [Details] |
| McDonnell, P., Lohfeld, S., O'Mahoney, D., McHugh, P.E. (2005) Rapid prototype models for mechanical characterisation of trabecular bone. Conference Paper [Details] |
| Lohfeld, S., McHugh, P.E., Serban, D., Boyle, D., O'Donnell, G., Peckitt, N. (2006) A comprehensive route for digital design of large customised maxillofacial prostheses in Engineering Assisted Surgery. Conference Paper [Details] |
| Lohfeld, S., McHugh, P.E., Serban, D., Boyle, D., O'Donnell, G., Peckitt, N. (2006) A route for digital design and manufacturing of customised maxillofacial implants. Conference Paper [Details] |
| O'Grady, H., Hynes, N., Hoary, M., McHugh, PE., Sultan, S. (2006) Analysis of abdominal aortic aneurysm (AAA) geometry using reconstructed 3-dimensional models of patient-specific aneurysms - a preliminary prospective study of 31 cases. Conference Paper [Details] |
| Zalatel, E., Quinlan, N., Nolan, P., Sultan, S., McHugh, P.E. (2006) Computer simulation to evaluate the efficacy of intermittent pneumatic compression on systemic blood circulation. Conference Paper [Details] |
| McGarry, J.P., Pathak, A., Valdevit, L., Evans, A.G., McHugh, P.E., McMeeking, R.M. (2006) Determination of contractile forces generated by actin fibre networks. Determination of contractile forces generated by actin fibre networks. Conference Paper [Details] |
| Coghlan, K.M., McHugh, P.E. (2006) Micromechanical model of the cytoskeletal network. Conference Paper [Details] |
| Breen, L. T., Murphy, B. P. and McHugh P. E. (2006) Novel bioreactor, mimicking arterial mechanical stimuli. Conference Paper [Details] |
| Donnelly, E., Mulryan, D., Connolley, T., McHugh, P.E. (2006) Three dimensional X-ray diffraction study of strain distribution in steel stent wire. Conference Paper [Details] |
| Harewood, F., McHugh, P.E. (2006) 3D modelling of cardiovascular stent performance. Conference Paper [Details] |
| Flaherty, B., McGarry, J.P., Murphy, B.P., McHugh, P.E. (2006) A continuum finite element mode predicting cell motility. Conference Paper [Details] |
| Lohfeld, S., Tyndyk, M.A., Barron, V., McHugh, P.E. (2006) Assessment of SLS fabricated scaffolds for skeletal reconstruction in the spine. Conference Paper [Details] |
| Tyndyk, M.A., Barron, V., McHugh, P.E. (2006) Effect of osteoporosis in the biomechanics of the thoracolumbar spine: finite element study. Conference Paper [Details] |
| Punchard, M.A., McHugh, P.E., Stenson-Cox, C., Barron, V. (2006) Mechanobiological response of endothelial cells in a bioreactor-model artery. Conference Paper [Details] |
| Punchard, M.A., Brougham, C., Mackle, J., Lyons, E., McHugh, P.E., Stenson-Cox, C., Barron, V. (2006) Response of endothelial cells to physiological mechanical forces. Conference Paper [Details] |
| Tyndyk, M. A., Barron, V. and McHugh, P. E. (2006) The effect of various bone conditions on the biomechanics of the thoracolumbar spine-finite element study. Conference Paper [Details] |
| Tyndyk, M.A., Lohfeld, S., Gundy, S., Barron, V., McHugh, P.E. (2006) SLS fabricated scaffolds for skeletal reconstruction in the spine. Conference Paper [Details] |
| You, X., Dowling, D., McHugh, P.E. (2006) Microscale modelling of wear behaviour of thin self-lubricating coatings. Conference Paper [Details] |
| Stops, A.J.F., O'Mahoney, D., McHugh, P.E. (2006) Mechano-regulation of cellular proliferation in an artificial scaffold. Conference Paper [Details] |
| Donnelly, E., Connolley, T., McHugh, P.E., Bruzzi, M.S., Nash, D., Mullryan, D., Buffiere, J-Y., Sharif, F. (2006) Material characterisation, device evaluation, and finite element simulation - the complete package. Conference Paper [Details] |
| Lohfeld, S., Tyndyk, M.A., Barron, V., McHugh, P.E. (2006) Manufacturing of small featured PCL scaffolds for bone tissue engineering using selective laser sintering. Conference Paper [Details] |
| Ganly, S., McMahon, J., Barron, V., McHugh, P.E., O'Brien, T. (2006) Investigation of non-viral gene delivery to the vasculature using a polymer-stent platform to combat ISR: A bioengineering approach. Conference Paper [Details] |
| O'Cearbhaill, E.D., McHugh, P.E., Stenson-Cox, C., Barron, V. (2006) Effect of Vascular Physiological Forces on Mesenchymal Stem Cell Differentiation. Conference Paper [Details] |
| Coghlan, K. M and McHugh P. E. (2006) Development of a discrete finite element cell model. Development of a discrete finite element cell model. Conference Paper [Details] |
| Breen, L.T., Murphy, B.P., McHugh, P.E. (2006) Analytical, computational and experimental validation of a vascular bioreactor. Conference Paper [Details] |
| Flaherty, B., McGarry, J. P., Murphy, B. P. and McHugh, P. E. (2006) A continuum finite element model predicting cell motility. Conference Paper [Details] |
| McDonnell, P., Harrison, N., O'Mahoney, D., McHugh, P.E., Lohfeld, S. (2006) Compression testing of trabecular bone with microscope video recording of failure mechanisms. Conference Paper [Details] |
| Harewood, F., McHugh, P.E. (2006) Microscale modelling of the mechanical behaviour of cardiovascular stents. Conference Paper [Details] |
| Harrison, N., O'Mahoney, D., McHugh P.E. (2006) To assess a high resolution voxel finite element modelling system of trabecular bone. Conference Paper [Details] |
| Flaherty, B., Murphy, B.P., McHugh, P.E. (2006) A continuum model for cell motility. Conference Paper [Details] |
| O'Grady, H., Hynes, N., Hoary, M., Sultan, S., McHugh, P.E. (2006) Computer Aided Engineering and Finite Element Analysis of Abdominal Aortic Aneurysm rupture. Conference Paper [Details] |
| Stops, A.J.F., O'Mahoney, D., McHugh, P.E. (2006) Mechano-regulation of cellular proliferation and differentiation in an artificial scaffold. Conference Paper [Details] |
| Mullins, L., Bruzzi, M.S., McHugh P.E. (2006) An indentation fracture study of cortical bone. An indentation fracture study of cortical bone. Conference Paper [Details] |
| Punchard, M.A., Barron, V., McHugh, P.E. (2006) Bioreactors and tissue engineered coronary arteries. Conference Paper [Details] |
| O'Cearbhaill, E. D., Barron, V. , McHugh, P.E. (2006) Building blood vessels. Conference Paper [Details] |
| Harrison, N., O'Mahoney, D., McDonnell, P., McHugh, P.E. (2006) Damage and failure of trabecular bone with non-linear geometry and inhomogeneous material properties. Conference Paper [Details] |
| O'Cearbhaill, E., Barron, V., Murphy, M., Barry, F., McHugh, P.E. (2006) Effect of a 3D fibrin scaffold on the multipotentiality of human mesenchymal stem cells. Conference Paper [Details] |
| Mullins, L., Bruzzi, M.S., McHugh P.E. (2006) The Nature of Plastic Flow in Bone. Poster Presented at the 52ND Annual Meeting of the Orthopaedic Research Society. Conference Paper [Details] |
| O'Cearbhaill, E., Barron, V., Murphy, M., Barry, F., McHugh, P.E. (2006) Towards an autologous tissue engineered vascular graft. Conference Paper [Details] |
| Mc Donnell, P. et al. (2006) The use of rapid prototype models for investigation of failure mechanisms in trabecular bone. Conference Paper [Details] |
| Mc Donnell, P. et al. (2007) A Finite Element Bone Loss Algorithm Applied to Vertebral Trabecular Bone. Conference Paper [Details] |
| Flaherty, N., Behan, N., Devery, D., McHugh, P.E., Barron, V. (2007) Evaluation of cytotoxicity methods for examining 3D biomaterials. Conference Paper [Details] |
| O'Cearbhaill, E., Punchard, M., Barron, V., McHugh, P.E. (2007) Differentiation of mesenchymal stem cells under vascular physiological loading. Differentiation of mesenchymal stem cells under vascular physiological loading. Conference Paper [Details] |
| Zalatel, E., Quinlan, N., Nolan, P., Sultan, S., McHugh, P.E. (2007) Computer simulation to evaluate the hemodynamic effect of intermittent pneumatic compression on systemic blood flow. Conference Paper [Details] |
| Hopkins, C., McHugh, P.E., McGarry, P. (2007) Computational modelling of stent-based gene delivery. Conference Paper [Details] |
| McDonnell, P., Liebschner, M.,McHugh P.E. (2007) A new method for diagnosis of osteoporosis. Conference Paper [Details] |
| Mullins, L., Bruzzi, M.S., Sassi, V., McHugh P.E. (2007) Measurement of the microstructural toughness of trabecular and cortical bone using indentation fracture. Conference Paper [Details] |
| Coghlan, K.M., McGarry, J.P., Mofrad, M.R.K., McHugh, P.E. (2007) Development of a discrete finite element cell model. Development of a discrete finite element cell model. Conference Paper [Details] |
| Harrison, N., O'Mahoney, D., McHugh P.E. (2007) A novel large deformation damage and fracture modelling method for trabecular bone. Conference Paper [Details] |
| Mullins, L., Bruzzi, M.S., McHugh P.E. (2007) Mechanisoms which help prevent fracture in bone. Conference Paper [Details] |
| Cahill, S., Lohfeld, S., McHugh, P.E. (2007) Finite Element Modeling of Bone Tissue Engineering Scaffolds Produced by Selective Laser Sintering. Conference Paper [Details] |
| Stops, A.J.F., McMahon, L., O'Mahoney, D., McHugh P.E., Prendergast, P.J. (2007) A finite element prediction of cellular strain in a GAG scaffold. Conference Paper [Details] |
| Stops, A.J.F., McMahon, L., O'Mahoney, D., McHugh P.E., Prendergast, P.J. (2007) A finite element prediction of cellular strain in a highly porous scaffold. Conference Paper [Details] |
| Stops, A. J. F., McMahon, L. A., Prendergast, P. J. and McHugh P. E. (2007) Towards the understanding of the transfer of load from an artificial scaffold to cells seeded in-vitro. Conference Paper [Details] |
| Cahill, S., Lohfeld, S., McHugh, P.E. (2007) Analysis of bone tissue engineering scaffolds produced by selective laser sintering. Conference Paper [Details] |
| Zalatel, E., Nolan, P., Quinlan, N., McHugh, P.E., Sultan, S. (2007) Computer simulation to evaluate the efficacy of intermittent pneumatic compression on systemic blood circulation. Conference Paper [Details] |
| Donnelly, E.W., Bruzzi, M.S., Connolley, T., McHugh, P.E. (2007) Finite element comparison of performance related characteristics of balloon expandable stents. COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING. Conference Paper [Details] |
| Ganly, S., Hopkins, C., Barron, V., McMahon, J., Greiser, U., McHugh, P.E., O'Brien, T. (2007) Investigation of non-viral gene delivery to the vasculature using a polymer-stent platform to combat ISR. Conference Paper [Details] |
| Mullins, L., Bruzzi, M.S., McHugh P.E. (2007) New insights into toughening in cortical bone. Conference Paper [Details] |
| Mullins, L., Bruzzi, M.S., McHugh P.E. (2007) The Contribution of Mechanisms Ahead of, and Behind the Crack tip to Toughening in Cortical Bone, during Crack Propagation. Conference Paper [Details] |
| McGarry, J.P., Deshpande, V.S., Evans, A.G., McHugh, P.E., McMeeking, R.M. (2007) An active model of cell contractility based on stress fibre formation. Conference Paper [Details] |
| McDonnell, P., Lohfeld, P., McHugh, P.E. (2007) Applications for RP models in characterising the mechanical behaviour of trabecular bone. Conference Paper [Details] |
| Hopkins, C., McHugh, P.E., McGarry, P. (2007) Computer modelling of gene delivery from a coated stent. Conference Paper [Details] |
| Kavanagh, S., McGarry, J.P., McNamara, S.F., McHugh, P.E., Hutton, W.C. (2007) Development of a finite element model of an intervertebral disc to assess a new nucleus replacement device. Development of a finite element model of an intervertebral disc to assess a new nucleus replacement device. Conference Paper [Details] |
| Mullins, L., Bruzzi, M.S., McHugh P.E. (2007) Variation in the contribution of mechanisms to toughness in cortical bone during crack propagation. Conference Paper [Details] |
| Flaherty, B., McGarry, J. P. and McHugh P. E. (2007) A continuum finite element model predicting cell motility. Conference Paper [Details] |
| Harrison, N., McDonnell, P., Mullins, L., McHugh, P.E. (2007) A novel large deformation finite element approach to modelling micro-damage and micro-fracture in trabecular bone. Conference Paper [Details] |
| Hopkins, C., McGarry, P. and McHugh, P.E. (2008) Modelling of Stent Coating Integrity and Theraputic Product Elution. Proceedings of EBR’2008 the Endocoronary Biomechanics Research Congress. Marseille, France: Conference Paper [Details] |
| Harewood, F., McHugh, P.E. (2008) Computational modelling of the mechanical performance of cardiovascular stents during deployment using a linked micro and macroscale approach. Proceedings of the International Forum on Material Behaviour Across the Lengthscales. Wadham College, Oxford, UK: Conference Paper [Details] |
| Hopkins, C., McHugh, P.E. and McGarry, P. (2008) Computer modelling of cardiovascular stent coating damage. Proceedings of the ASME 2008 Summer Bioengineering Conference. Florida, USA: Conference Paper [Details] |
| McHugh, P.E. (2008) Computer modelling of stent design: geometrical accuracy and size effects. Proceedings of EBR’2008 the Endocoronary Biomechanics Research Congress. Marseille, France: Conference Paper [Details] |
| Hopkins, C., McHugh, P.E. and McGarry, P. (2009) Computational and experimental investigation into the delamination of biomedical stents coatings. Proceedings of the 8th International Conference on Fracture and Damage Mechanics. St. Georges Bay, Malta: Conference Paper [Details] |
| Lohfeld, S., Cahill, S., Bausewein, C., Kreja, L., Ignatius, A., Dürselen, L. and McHugh, P.E. (2009) Solid Freeform Fabricated PCL Composite Scaffolds for Long Bone Applications. Proceedings of the annual meeting of the Biomedical Engineering Society. Pittsburgh, PA, USA: Conference Paper [Details] |
| Grogan, J., Leen, S., McHugh, P.E. (2010) Modelling and experiments to aid performance assessment of biodegradable metallic stents. Texas, USA: Conference Paper [Details] |
| Ganly, S., Hynes, S., Sharif, F., Barron, V., McCullagh, K., McHugh, P.E., O'Brien, T. and Greiser, U. (2010) A comparison of gene delivery both in vitro and in vivo from phosphorylcholine-coated stents, using commercial and novel Lipoplex formulations. Proceedings of TERMIS-EU 2010, Tissue Engineering and Regenerative Medicine International Society-EU. Galway, Ireland: Conference Paper [Details] |
| Birmingham, E., McNamara, L., Niebur, G., McHugh, P.E. (2010) Understanding the biomechanical microenvironment of the stem cell niche in bone. Proceedings of the 17th European Society of Biomechanics Congress. Edinburgh, Scotland: Conference Paper [Details] |
| McHugh, P.E. (2010) Towards the estimation of minimum strut sizes in coronary stents. Proceedings of EBR’2010 the Endocoronary Biomechanics Research Congress. Marseille, France: Conference Paper [Details] |
| Stops. A.J.F., Harrison, N., Heraty, K., Browne, M., O'Brien, F.J. and McHugh, P.E. (2010) Computational modelling to explore the cellular micromechanical environment is a collagen-GAG scaffold. Proceedings of TERMIS-EU 2010, Tissue Engineering and Regenerative Medicine International Society-EU. Galway, Ireland: Conference Paper [Details] |
| Grogan, J., Leen, S., McHugh P.E. (2010) A phenomenological model of corrosion in biodegradable metallic stents. Proceedings of the 2010 ASME Summer Bioengineering Conference, paper SBC2010-19361. Florida, USA: Conference Paper [Details] |
| Zalatel, E., Quinlan, N., Nolan, P., Sultan, S., McHugh, P.E. Computer simulation to evaluate the efficacy of intermittent pneumatic compression on systemic blood circulation. Conference Paper [Details] |
| Mullins, L.P., Bruzzi, M.S., McHugh, P.E. Microcrack growth in cortical bone using indentation fracture. World Congress of Biomechanics Abstract published in Journal of Biomechanics. Conference Paper [Details] |
| Mullins, L.P., Bruzzi, M.S., McHugh, P.E. New insights into toughening in human cortical bone. Eniskillen, Co. Fermanagh: Conference Paper [Details] |
| Harrison, N.M., O'Mahoney, D., McHugh, P.E. To assess a high resolution voxel finite element modelling system of trabecular bone. Proceedings of the 14th Annual Symposium on Computational Methods in Orthopaedic Biomechanics. University of Illinois-Chicago Chicago, IL, USA: Conference Paper [Details] |
| McGarry, J.P., McHugh, P.E. Modelling of in-vitro chondrocyte detachment. Conference Paper [Details] |
| Bruzzi, M.S., Mullins, L.P., McHugh, P.E. An Indentation Fracture Study of Bone. Bioengineering In Ireland Conference. Galway, Ireland: Conference Paper [Details] |
| Stops. A.J.F., Harrison, N., Heraty, K., Browne, M., O'Brien, F.J., McHugh, P.E. Computational modelling to explore the cellular micromechanical environment is a collagen-GAG scaffold. Proceedings of TERMIS-EU 2010, Tissue Engineering and Regenerative Medicine International Society-EU. Conference Paper [Details] |
Conference Poster
| Mullins, L.P., Bruzzi, M.S., McHugh, P.E. The relative contribution of toughening ahead of and behind the crack tip in human cortical bone during crack propagation. 53ND Annual Meeting of the Orthopaedic Research Society. San Diego, California, USA: Conference Poster [Details] |
Editorial
| McHugh, PE,Schmauder, S (2002) Computational mechanics of materials - Selected Papers of the Tenth International Workshop - National University of Ireland, Galway, Ireland 31 August-1 September, 2000 - Preface. Editorial [DOI] [Details] |
Invited papers
| McHugh, P.E. (1991) Prediction of the mechanical performance of MMCs. Invited papers [Details] |
| McHugh, P.E. (1992) Finite element micromechanical modelling of MMCs. Invited papers [Details] |
| McHugh, P.E. (1993) Supercomputers and finite elements in prosthesis design. Invited papers [Details] |
| Quinn, D., Connolly, P., McHugh, P.E. (1994) Computational analysis of void growth and interface debonding in a crystalline material. Invited papers [Details] |
| McHugh, P.E. (1994) Finite element modelling of deformation in crystalline material. Invited papers [Details] |
| McHugh, P.E. (1995) Micro and macro mechanics of metals and metal matrix composites. Invited papers [Details] |
| McHugh, P.E. (1996) Creep in nickel base superalloy single crystals. Invited papers [Details] |
| McHugh, P.E. (1996) Crystal plasticity theory and examples of its application. Invited papers [Details] |
| McHugh, P.E. (1996) Micromechanical modelling of single crystals, polycrystals and MMCs. Invited papers [Details] |
| McHugh, P.E. (1996) Applications of a liquid phase sintering model. Invited papers [Details] |
| McHugh, P.E. (1996) Modelling the sintering of silicon nitride and tungsten carbide. Invited papers [Details] |
| McHugh, P.E. (1997) Modelling sintering using finite elements. Invited papers [Details] |
| Quinn, D., Connolly, P., McHugh, P.E. (1997) Computational modelling of void growth in metallic single crystals. Invited papers [Details] |
| McHugh, P.E. (1998) Computational modelling of ductile crack growth in WC-Co. Invited papers [Details] |
| McHugh, P.E. (1998) Computational modelling of ductile failure in a metal-ceramic composite. Invited papers [Details] |
| McHugh, P.E. (1998) Modelling of ductile failure in cobalt using crystal plasticity. Invited papers [Details] |
| Bruzzi, M. S. and McHugh, P. E. (1999) Modelling the mechanical behaviour of MMCs in static loading. Invited papers [Details] |
| McHugh, P.E. (1999) Computational micromechanics in engineering analysis. Invited papers [Details] |
| McHugh, P.E. (1999) Review of crystal plasticity theory. Invited papers [Details] |
| McHugh, P.E., Farrissey, L. (1999) Computational micromechanics: examples of applications. Invited papers [Details] |
| McHugh, P.E. (2000) Computational Micromechanics: Examples of Applications in the Aerospace, Automotive and Biomedical Industries. Invited papers [Details] |
| McHugh, P.E. (2001) National Centre for Biomedical Engineering Science at NUI, Galway: Centre development and progress in research. Invited papers [Details] |
| McHugh, P.E. (2001) Applications of biomedical engineering science in medical devices. Invited papers [Details] |
| McHugh, P. E., Tyndyk, M., McGarry, J. G., O'Donnell, B. P. and McGarry J. G. (2001) Finite element analysis in biomedical engineering and the design of medical devices. Invited papers [Details] |
| McHugh, P.E. (2001) Computational micromechanics: examples of applications to MMCs and stainless steels. Invited papers [Details] |
| McHugh, P.E. (2002) Biomechanics Research at the National Centre for Biomedical Engineering Science. Invited papers [Details] |
| McHugh, P.E. (2002) National Centre for Biomedical Engineering Science: Facilities and Research. Invited papers [Details] |
| McHugh, P.E. (2002) Research at the National Centre for Biomedical Engineering Science. Invited papers [Details] |
| McHugh, P.E. (2003) Size effects in analytical modelling of biomaterials. Invited papers [Details] |
| McHugh, P.E. (2003) Computational micromechanics applied to medical devices. Invited papers [Details] |
| McHugh, P.E., Barron, V., Murphy, B. (2003) Overview of the NCBES. Invited papers [Details] |
| McHugh, P.E. (2004) Computational Methods in Biomechanics: Fundamentals and Applications. Invited papers [Details] |
| Lohfeld S., McHugh, P.E. (2004) Digital technologies in biomedical engineering - a view to the future. Invited papers [Details] |
| McHugh, P.E. (2004) Continuum micromechanics of materials. Invited papers [Details] |
| McHugh, P.E. (2004) Experimental and computational research in biomedical engineering. Invited papers [Details] |
| McHugh, P.E. (2004) Examples of finite element modelling applied to medical devices and tissue. Invited papers [Details] |
| McHugh, P.E. (2004) Computational modelling in biomedical engineering: devices and tissue. Invited papers [Details] |
| McHugh, P.E. (2005) The role of engineers in medical technology industry: Infrastructure and Education Defining our future in medical technology. Invited papers [Details] |
| McHugh, P.E. (2005) Finite element analysis and computational and physical prototyping. Invited papers [Details] |
| McHugh, P.E. (2007) Industry involvement in a Graduate Research Education Programme in Biomedical Engineering. Invited papers [Details] |
| McHugh, P.E. (2007) Computational modelling of vascular stent deployment in tortuous geometries. Invited papers [Details] |
| McHugh, P.E. (2007) Development of a Graduate Research Education Programme in Biomedical Engineering. Invited papers [Details] |